1. |
Structural Detail Design of the following buttlist items: |
|
a. BM-001/012 |
|
- To extend the existing GUE Crane Sheath Maintenance Platform
- To add swivel davit with capacity of 200lbs at the edge of Sheave Maintenance Platform deck. (by Structural)
|
|
b. BM-019 |
|
- To fabricate and install work access platform at Guntong D Compression for the access of Isolation Ball Valve on the back-up fire water supply line to Guntong D from Guntong E.
|
|
c. BM-025 |
|
- To install additional/modified service platforms at vessels
|
|
d. BM-030 |
|
- To modify firewall between each firewater pump and the attached pipe supports to make them removable for access during removal of the firewater pump engine.
|
|
|
2. FEED and Detail Design:- |
|
a. BM-003 |
|
- Modifications required to provide access for tube bundle removal for fuel and seal gas superheaters and fuel gas heat exchanges: includes piping rerouting, shutdown valve actuator relocation, cable tray relocation, deck extensions (north and west sides), and instruments stands relocation.
|
|
b. BM-010 |
|
- To propose design modification in order to condition back-up fuel gas & seal gas.
|